TH26077 Dielectric test fixture

Frequency range: DC-120MHz

DUT size: 10mm-56mm

DUT thickness: ≤10mm

Suitable for: TH2839/ TH2838/ TH2829/ TH2827/ TH2826 and other series


......
TH26061C Test fixture

Frequency range: DC-1MHz

Maximum DC current: ±100A

Applicable to: TH1778/TH1778S series


......
TH26061D Test Fixture

Frequency range: DC-1MHz

Maximum DC current: ±60A

Applicable to: TH26061C


......
TH26008B Magnetic ring fixture

Frequency range: DC-120MHz

Maximum bias current: ±42V

Applicable to: SMD devices, high-frequency small capacitors and small inductances.

         When the test frequency is ≥100kHz, the capacity is ≤3pF, or the inductance is ≤1µH, this type of SMD fixture is suitable.


......
TH26108C High frequency patch fixture

Frequency range: DC-40 MHz

Maximum offset: ±42 V

Applicable to: LCR series, (SMD components)


......
TH17761 TH17761 Fixture Box

Frequency range: DC-1MHz

Maximum DC current: ±40A

Applicable to: TH1776


......
TH26001 Four-end fixture

Frequency range: DC-10kHz

Maximum DC bias: DC ±42V

Applicable to: axial component test at both ends, all LCR, capacitance meter, inductance meter


......
TH26001A Four-end fixture

■ Frequency range: DC-10kHz

Maximum DC bias: DC ±42V

Applicable to: axial component test at both ends, all LCR, capacitance meter, inductance meter


......
TH26002 Fixtures at both ends

Frequency range: DC

Maximum DC bias: DC 0-650V

Applicable to: TH2685/86, TH2681/A


......
TH26003 Tip clamps at both ends

Frequency range: DC

Maximum DC bias: DC 0-650V

Applicable to: TH2615E, TH2685/A/C, TH2686/A/C, TH2687C, TH2689 series


......
TH26005A Four-end fixture

Frequency range: DC-100KHz-300KHz

Maximum DC bias: ±42V

Axial component test at both ends of the small pitch can be used for axial component test in conjunction with TH26006

*Testing equipment: TH28 series, TH2817A/TH2816A/TH2816B

     *Terminal connection: BNC, four-terminal

     *Frequency: up to 100kHz~300kHz


......
TH26005B Four-end clamp with card

Frequency range: DC-5 MHz

Maximum DC bias: ±42V

Used for testing of axial components at both ends of the small pitch. With TH26006, it can be used for testing of axial components.

Applicable to: Except TH2828/TH2838/TH2839 series other electric bridges


......
TH26005C Four-end clamp with card

Frequency range: DC-120 MHz

Maximum DC bias: ±42V

Used for testing of axial components at both ends and TH26006 can be used for testing of axial components.

Applicable to: TH2828/TH2838/TH2839 series/TH2826 series.


......
TH26006 Radial clamp

Applicable to: need to be used in conjunction with TH26005A/TH26005B/TH26005C

......
TH26007 Magnetic ring clamp

Frequency range: DC-120MHz

Maximum bias current: ±42V

Small magnetic ring single-turn inductance test, the size can be customized according to customer needs.

■ Applicable to: LCR and inductance tester


......
TH26007A Magnetic ring clamp

Frequency range: DC-120MHz

Maximum bias current: ±42V

Small magnetic ring single-turn inductance test, the size can be customized according to customer needs.

Applicable to: LCR and inductance tester


......
TH26008 Magnetic ring fixture

Frequency range: DC-120MHz

Maximum bias current: ±42V

Applicable to: SMD devices, high-frequency small capacitors and small inductances.

         When the test frequency is ≥100kHz, the capacity is ≤3pF, or the inductance is ≤1µH, this type of SMD fixture is suitable.


......
TH26008A Magnetic ring fixture

Frequency range: DC-120MHz

Maximum bias current: ±42V

Applicable to: SMD devices, high-frequency small capacitors and small inductances.

         When the test frequency is ≥100kHz, the capacity is ≤3pF, or the inductance is ≤1µH, this type of SMD fixture is suitable.


......
TH26015 Charging fixture

Frequency range: DC

Working voltage: DC 0-650V

Applicable to: can be used with all leakage meters


......
TH26038 Transformer test fixture

Frequency range: DC-10kHz

Maximum DC bias: ±42V

Lead length: 0.8m

Suitable for: TH2817C/TH2825A, TH2827


......
TH26047 Fixture

Frequency range: DC-120 MHz

Maximum DC bias: ±42V

Applicable to: Desktop LCR meter


......
TH26048 Fixture

Frequency range: DC-13 MHz

Maximum DC bias: ±42V

Applicable to: Desktop LCR meter


......
TH26049 2817CX fixture

Frequency range: DC-100kHz

Maximum DC bias: ±42V

Applicable to: TH2817CX


......
TH26004B Test line at both ends

Frequency range: DC

Working voltage: DC 0-1000V

Lead length: 0.8m

Suitable for: TH2685/86, TH2681/A, TH2684/A, TH2683A/B, etc.


......
TH26004D Three-terminal test line

Frequency range: DC

Working voltage: DC 0-1000V

Lead length: 0.5m

Applicable to: TH2683, TH2689


......
TH26004E-1 Bias current source link cable

Frequency range: DC-1MHz

Applicable to: TH1772B/73/75/76/78 series bias current source when matched with LCR


......
TH26009B Box patch test cable

Frequency range: DC-15 MHz

Maximum current: ±42V

Lead length: 0.8m

Applicable to: used for testing various SMD devices, applicable to all LCRs, capacitance meters, inductance meters


......
TH26009C TH2822 patch test cable

Frequency range: DC-15 MHz

Maximum current: ±42V

Lead length: 0.8m

■ Applicable to: TH2822 series


......
TH26011 Four-terminal Kelvin test line with box

Frequency range: 5Hz to 100kHz

Maximum bias current: ±42V

Lead length: 0.8m

Applicable to: all LCR digital bridges


......
TH26011A Kelvin test lead with box four-terminal insulation and lock

Frequency range: 5Hz to 100kHz

Maximum bias current: ±42V

Lead length: 0.8m

Applicable to: Four-terminal pair of instruments such as TH2828, TH2828A, TH2828S, TH2826, TH2826A can be used with other LCR instruments to obtain better measurement results


......
TH26011B Kelvin test lead with box four-terminal insulation and lock

Frequency range: 5Hz to 100kHz

Maximum bias current: ±42V

Lead length: 0.8m

Applicable to: Four-terminal pair of instruments such as TH2828, TH2828A, TH2828STH2826, TH2826A can be used in other LCR instruments to obtain better measurement results


......
TH26013 DC bias test clip leads

Frequency range: DC-1MHz

Maximum bias current: ±20V

Lead length: 0.8m

 Applicable to: TH1772B/1773/1775


......
TH26023 Four-terminal test line

Frequency range: 5Hz-100kHz

Maximum DC current: ±42V

Lead length: 0.8m

Applicable to: LCR series


......
TH26023A Test line at both ends

Frequency range: 5Hz-100kHz

Maximum DC current: ±42V

Lead length: 0.8m

Applicable to: LCR series


......
TH26027 TH2821 four-terminal Kelvin test cable

Frequency range: 5Hz-100kHz

Maximum DC current: ±42V

Lead length: 0.8m

Applicable to: TH2821 series


......
TH26029 TH2821 SMD test cable

Frequency range: 5Hz to 100kHz

Maximum DC current: ±42V

Lead length: 0.8m

Applicable to: TH2821 series


......
TH26029B Box patch test cable

Frequency range: 5Hz to 100kHz

Maximum DC current: ±42V

Lead length: 0.8m

Applicable to: Desktop LCR


......
TH17761-01 Connection cable

■ For TH1776

......
TH17761-02 Connection cable

Applicable to: TH1776

......
TH26028(CCC) National standard adapter

Output: DC 12V, 200mA

Applicable to: TH2822 series


......
TH17761-03 Ground short-circuit wire

Applicable to: TH1776

......
TH26004C Test line at both ends

Frequency range: DC

Working voltage: DC 0-650V

Lead length: 0.8m

Suitable for: TH2688C, TH2685A/C, TH2686A/C, TH2687C, etc.


......
TH26004F(JC-BBC03009) Handheld meter test cable

Frequency range: DC-10kHz

Maximum DC bias: DC ±42V

Applicable to: TH2822 series


......
TH26042(2H/57S-3050*2/L 1200) 50 core interface cable

Applicable to: TH1776

......
TH26010 Short circuit

Applicable to: Used for short-circuit clearing of various LCR testers.

......
TH26010B Short circuit

Applicable to: TH2821, TH2822 series

......
TH26059 Large capacitance test fixture

Frequency range: DC-100kHz

Maximum DC bias: ±42V

Applicable to: LCR series, can test bolt capacitors


......
TH26048A Fixture

Frequency range: DC-13 MHz

Maximum DC bias: ±42V

Applicable to: TH2830/31/32 series, and full range of LCR


......
TH26048A-1 Fixture accessory

Applicable to: TH26048A short pin test accessory

......
TH26048A-2 Fixture accessories

Applicable to: TH26048A axial test accessories

......
TH26011AS Kelvin test lead with box four-terminal insulation and lock

Frequency range: 5Hz to 100kHz

Maximum bias current: ±42V

Lead length: 0.8m

Applicable to: all LCR digital bridges


......
TH26062A Test Fixture

Frequency range: DC-120MHz

Maximum DC bias: ±42V

Applicable to: TH2638A/TH2838/TH2839, testing large-capacity film capacitors (square) for electric vehicles, only short-circuit clearing.


......
TH26009D Box patch test cable

Frequency range: DC-15 MHz

Maximum current: ±42V

Lead length: 0.8m

Applicable to: TH2638 series


......
TH1778-01 Test Fixture

Frequency range: DC-1MHz

Maximum DC current: ±20A

Applicable to: TH1778


......
TH1778-02 Test Fixture

Frequency range: DC-1MHz

Maximum DC current: ±60A

Applicable to: TH1778


......
TH1778-03 Test Fixture

Frequency range: DC-1MHz

Maximum DC current: ±120A

Applicable to: TH1778


......
TH26063 Test Fixture

Frequency range: DC-10MHz

Maximum DC bias: ±42V

Applicable device size: center distance 32mm

Applicable to: TH2638A/TH2838/TH2839 series LCR series, can test bolt capacitors (cylindrical)


......
TH26011BS Kelvin test lead with box four-terminal insulation and lock

Frequency range: 5Hz to 100kHz

Maximum bias current: ±42V

Lead length: 0.8m

Applicable to: Four-terminal pair instruments such as TH2828, TH2828A, TH2828STH2826, TH2826A can be used with other LCR instruments to obtain better measurement results


......
TH26011CS Kelvin test lead with box four-terminal insulation and lock

Frequency range: 5Hz to 100kHz

Maximum bias current: ±42V

Lead length: 0.8m

Applicable to: TH2830 series, TH2523 series and other LCR instruments except TH2828, TH2838, TH2839 series


......
TH26027AS Test Cable

Frequency range: 5Hz-100kHz

Maximum DC current: ±42V

Lead length: 0.8m

Applicable to: TH2822 series


......
TH26004S-1 Four-terminal Kelvin test cable

Frequency range: DC-10kHz

Maximum DC bias: DC ±42V

Lead length: 0.8m, 1.5m, 2m

Applicable to: conventional LCR is not applicable to four-terminal pair instruments such as TH2828 series and TH2838 series


......
TH26063A Test Fixture

Frequency range: DC-10MHz

Maximum DC bias: ±42V

Applicable device size: center distance 50mm

Applicable to: TH2638A/TH2838/TH2839 series LCR series, can test bolt capacitors (cylindrical), only short-circuit clearing.


......
TH26004E-2 Test Box

Frequency range: DC-1MHz

Applicable to: TH1778 series bias current source when matched with LCR


......
TH26069 Fixture

For TH1778A

......
TH26047A Fixture

Frequency range: DC-120 MHz

Maximum DC bias: ±42V

Applicable to: Desktop LCR meter


......
TH26078 Test Fixture

Frequency range: ≤100kHz

Protection voltage: C<2μF 1000V Max

         C>2μF image.pngV Max

Applicable to: Suitable for all LCR and capacitance testers, TH2638 testing large capacitors must ensure that the capacitor is not charged, low-voltage large capacitors will also cause damage to TH2638


......
TH26028A Adapter INPUT: 100-240V~50/60HZ, OUTPUT: 5V=1A

Output: DC 12V, 200mA

Applicable to: TH2822M series


......
TH26011D Kelvin test line with box four ends with lock

Frequency range: DC-100kHz

Maximum bias voltage: ±150V

Applicable to: LCR instrument superimposed external DC voltage test


......
TH26049A 2817C fixture

Frequency range: DC-100kHz

Maximum DC bias: ±42V

Applicable to: TH2817C+


......
TH26023B BNC four-terminal pair cable
......
TH26082 100Ω standard resistance
......
TH26009E SMD component test clamp

Frequency range: DC-15 MHz

Maximum current: ±42V

Lead length: 0.8m

Applicable to: used for testing various SMD devices,

   Suitable for all LCR, capacitance meter, inductance meter


......
TH26082A
......
TH2851校准套件 TH2851 calibration kit
......
TH26005D
......
TH26048B
......
TH26011E
......
TH26086
......
TH26088
......
TH26087D
......
TH26047B
......
TH26011BS-T
......